Non-Cladding Remediation Services

Not every façade defect is caused by the cladding.

Trident Facades provides non-cladding remediation services for buildings where defects or safety concerns involve other components of the external wall or building envelope.

This can include insulation, cavity barriers, fire stopping, windows, balconies, waterproofing, render and façade interfaces.

What Is Non-Cladding Remediation?

Non-cladding remediation addresses defects within the external wall or façade that are separate from the visible cladding system. Examples include defective insulation, missing cavity barriers, fire-stopping defects, failed membranes, water ingress, window defects, balcony defects, render failure, deteriorated substrates, defective interfaces, corrosion, and structural façade defects.

Non-Cladding Remediation Services

Our non-cladding remediation service includes:

  • Review of existing assessment information and fire risk reports
  • External wall and envelope investigation
  • Opening-up and intrusive investigation
  • Concealed component condition assessment
  • Insulation performance and installation assessment
  • Cavity barrier and fire-stopping deficiency assessment
  • Breathable membrane and waterproofing assessment
  • Window, balcony, and substrate condition surveys
  • Façade interface and structural defect assessment
  • Remediation strategy and optioneering
  • Design and specification for non-cladding elements
  • Insulation replacement and upgrading
  • Cavity barrier and compartmentation fire stopping remediation
  • Window and balcony remediation works
  • Waterproofing and render repairs
  • Substrate and structural façade repairs
  • Interface and junction detailing
  • Making good
  • Completion

Why Non-Cladding Defects Matter

Removing or replacing cladding does not necessarily resolve problems within the rest of the external wall.

For example, a façade may have:

New cladding + defective insulation

or:

Replacement panels + inadequate cavity barriers

or:

Sound cladding + failed waterproofing

A successful remediation project therefore needs to address the complete wall construction where required.

Coordinated Façade Remediation

Trident Facades can coordinate non-cladding works alongside:

  • Cladding remediation
  • Cladding replacement
  • Curtain wall remediation
  • External wall replacement
  • Façade waterproofing
  • Fire-stopping remediation

This allows different façade components to be addressed as one coordinated remediation project.

Our Non-Cladding Remediation Process

  • Assessment

    1

    A thorough investigation of the building envelope to identify hidden defects, compartmentation failures, or performance issues outside of the primary cladding system.

    Reviewing existing assessment reports, conducting intrusive opening-up works, and assessing concealed components such as insulation, cavity barriers, fire stopping, membranes, and structural interfaces.

  • Strategy

    2

    Developing a targeted remediation plan based on the envelope investigation findings.

    Determining whether the building requires localised repairs, component replacements, or coordinated upgrades to non-cladding elements like windows, balconies, waterproofing, or fire barriers.

  • Design

    3

    Engineering the required non-cladding remediation into a clear, buildable specification.

    Developing detailed technical packages covering compliant insulation replacements, certified cavity barrier and fire-stopping layouts, waterproofing details, and structural interface connections

  • Removal

    4

    Safely stripping away defective or non-compliant non-cladding components within the wall build-up.

    Erecting necessary access or containment, carefully removing degraded insulation, failed membranes, inadequate cavity barriers, and compromised fire stopping without damaging surrounding sound structures.

  • Repair

    5

    Repairing and upgrading the underlying structure, framing, and fire barriers.

    Correcting structural interfaces, installing proper mechanical fixings and support framing, and fitting certified cavity barriers and fire stopping at all critical junctions.

    See Our Timber Cladding Repair Service 

  • Replacement

    6

    Rebuilding and upgrading the non-cladding building envelope elements to modern performance standards.

    Installing new non-combustible insulation, continuous breather membranes, replacement windows or balcony details, and reinstating proper weather-sealing and waterproofing measures.

  • Completion

    7

    Final handover, quality verification, and project sign-off.

    Making good work areas, conducting rigorous quality and compliance inspections, and issuing the necessary completion documentation, safety certifications, and warranties.

Talk to Trident Facades about non-cladding façade remediation.

Tell us briefly about your requirements